KEW SNAP
Series
KEW SNAP 2413R
DIGITAL CLAMP METER
KYORITSU ELECTRICAL INSTRUMENTS
WORKS,LTD.
INSTRUCTION MANUAL
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - KEW SNAP

KEW SNAPSeriesKEW SNAP 2413RDIGITAL CLAMP METERKYORITSU ELECTRICAL INSTRUMENTSWORKS,LTD.INSTRUCTION MANUAL

Strany 2 - Contents

―8―Operating System :Dual IntegrationDisplay :Field effect 3・1/2 digit liquid crystaldisplay with maximum count of 1999Range selection :ManualOverran

Strany 3 - 1.Safety Warnings

① LCDField effect liquid crystal display with maximum indication of 1999.Function symbol(mA, A) and decimal point automatically appear asthe function

Strany 4

―10―“”is displayed on the lower right side for low batterywarning and “1”is displayed only at the highest digit foroverrange indication.② Data Hold Bu

Strany 5 - CAT.III

―11―5.Operation5-1 Preparation(1) To Check battery set the function/range switch ⑤ To the desiredposition. If the display is clear without symbol “”sh

Strany 6 - 2.Features

―12―CAUTION●Transformers jaws , especially their tips, have been preciselyadjusted to obtain maximum accuracy. Take sufficient care toavoid shock, vib

Strany 7 - 3.Specifications

―13―Note:When measuring large current, observe the time limit specified insection 3, Specifications. Otherwise, the transformers jaws mayoverheat, res

Strany 8

―14―5-3 How to Use Peak Hold Function10ms or 100ms response time can be selected for peak holdmeasurement. Make selection according to your applicatio

Strany 9

―15―Note 2:If it is necessary to read the display away from the conductorin a peak hold measurement, press the data hold switch ②first and then remove

Strany 10

―16―5-4 How to Use The Frequency Selector SwitchKEW SNAP 2413R has a very good frequency response because of theelectromagnetic property of its transf

Strany 11 - 4.Instrument Layout

―17―5-5 How to Use Data Hold FunctionPush in the Data Hold button to freeze the reading. This is especiallyuseful for taking a reading in a dimly lit

Strany 12

Contents1.Safety Warnings ………………………………………………………12.Features ………………………………………………………………43.Specifications …………………………………………………………54.Instrument Layout

Strany 13 - 5.Operation

―18―KEW SNAP 2413R5-7 Analogue Output: How to Use Model 7073 Output CordAC and DC output can be obtained by inserting optional Model 7073output cord i

Strany 14

Replace the battery when“”symbol appears on the LCD.(1) Set the function/range switch to the OFF position.(2) Unscrew and remove the battery compartme

Strany 15

―20―Use a damp cloth detergent for cleaning the body of the instrument. Toavoid possible deforming or discoloring, do not use solutions containingsolv

Strany 16

―21―Use the following troubleshooting guide for hints on problems withinstrument operation.8.Before Sending for RepairTransformer jaws buzzwhen measur

Strany 17

06-12DISTRIBUTOR92-1870AKyoritsu reserves the rights to change specifications ordesigns described in this manual without notice and withoutobligations

Strany 18

―1―1.Safety WarningsMake sure to read through this instruction manual before using thisinstrument.●The instrument has been designed, manufactured, and

Strany 19 - 5-6 How to use Back Light

Following symbols are used on the instrument and in the instructionmanual. Attention should be paid to each symbol to ensure your safety. Refer to the

Strany 20 - KEW SNAP 2413R

―3―CAUTION●Make sure that the function selector switch is set to anappropriate position before making measurement.●Be sure to set the function selecto

Strany 21 - 6.Battery Replacement

―4―KEW SNAP 2413R is a unique digital clamp meter for both very lowcurrent and high current measurements. Its shielded transformers jawsminimizes the

Strany 22 - 7.Cleaning

―5―Measuring Ranges and Accuracy●AC Current 3.Specifications● Effective Value (RMS)Most alternating currents and voltages are expressed in effectiveva

Strany 24 - 92-1870A

―7―Range200mA2A20A200A1000AMeasuring Range0∼200mA0∼2A0∼20A0∼200A0∼500A501A∼1000AAC Output VoltageAccuracy0∼200mV±2.0%rdg±0.5mV±2.5%rdg±0.5mV±3.0%rdg±0